Analog Way Smart Edge FX - STE200 Programmer's Guide User Manual

Page 49

Advertising
background image

49

Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

Index #3

SOFTEDGE

SOFTEDGE_MODE

JM JM SoftEdge blending mode

Rd/Wr 0

1

0

SOFTEDGE_COVERING_SIZE

JZ

JZ Covering size

Rd/Wr 0

1023 0

Unit = pixels

SOFTEDGE_ENABLE_CURVES

JE

JE Enable the SoftEdge curves

Rd/Wr 0

1

0

0 = no SoftEdge

SOFTEDGE_POINT

Jp

Jp Dots of the SoftEdge curves

Rd/Wr 0

65535 32768

Unit = percent, 1 dot X Y (X=
LSB, Y = MSB)

0 = Top/Left border
1 = Bottom/Right
border

0 = Dot 0
1 = Dot 1

0 = X
position
1 = Y
position

SOFTEDGE_BLACK_SIZE

Jb

Jb Black level correction area size

Rd/Wr 0

127

0

Unit = pixels

0 = Top/Left border
1 = Bottom/Right
border

0 = Back End
1
1 = Back End
2

SOFTEDGE_BLACK_R_LEVEL

JR

JR R component of the black level

Rd/Wr 0

63

0

0 = Black, 63 = Max Luma

0 = Top/Left border
1 = Bottom/Right
border

SOFTEDGE_BLACK_G_LEVEL

JG JG G component of the black level

Rd/Wr 0

63

0

1 = Black, 63 = Max Luma

0 = Top/Left border
1 = Bottom/Right
border

SOFTEDGE_BLACK_B_LEVEL

JB

JB B component of the black level

Rd/Wr 0

63

0

2 = Black, 63 = Max Luma

0 = Top/Left border
1 = Bottom/Right
border

PREVIEW_MODE

Jm Jm Activate the unified preview

Rd/Wr 0

1

0

REFERENCEREFREQUEST

Xr

Xr

Framelock source requested by
user

Rd/Wr 0

16

0

0 = Analog input 1 as
reference
1 = Analog input 2 as
reference
2 = Analog input 3 as
reference
3 = Analog input 4 as
reference
4 = Analog input 5 as
reference
5 = Analog input 6 as
reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
12 = SDI 3 input as reference
13 = SDI 4 input as reference
14 = Back End 1 as
reference
15 = Back End 2 as
reference
16 = Back End 3 as
reference

0 = Main output
1 = Preview output
2 = Recording
output

Advertising