Read Time-Out

Use this selection to set a time-out (in milliseconds) of the
imager’s trigger if the imager is in manual trigger mode. Once the

imager has timed out, you can activate the imager by pressing the

trigger. After scanning the Read Time-Out bar code, set the

time-out duration (from 0-300,000 milliseconds) by scanning

digits from the inside back cover, then scanning Save. Default = 0

(infinite, or no time-out).

Low Power Time-Out Timer

Scan the Low Power Time-Out bar code to change the time-out

duration (in seconds). Then scan the time-out duration (from 0-300

seconds) from the inside back cover, and Save. Default = 120

seconds. If the unit remains idle during the low power time-out

interval, the unit goes into low power mode. Whenever the trigger

is enabled, the low power time-out timer is reset.

Auto-sense LED Behavior after Decode

When an imager is in Auto-sense mode, the LEDs remain on and

continue scanning for a short time after a bar code is decoded. If

you wish to turn the LEDs off immediately after a bar code is

decoded, scan the LEDs Off bar code, below. Default = LEDs On.

Auto-sense LED Time-Out

When using Auto-sense LED Behavior after Decode , you may

want to set the time the LEDs remain off after a decode. To set the

duration of this delay, scan the bar code below, then set the

time-out by scanning digits (0 - 9,999 ms) , then scanning Save.

Once the unit has completed this time-out, it will immediately

resume scanning.

Auto-sense Sensitivity

Auto-sense Sensitivity is a numeric range that increases or

decreases the imager's reaction time to bar code Auto-sense. To set

the sensitivity, scan the Sensitivity bar code, then scan the degree

Advertising