3 requirements, 1 environmental requirements, Table 2-2 – Artesyn MVME7100 Single Board Computer Installation and Use (June 2014) User Manual
Page 29: Mvme7100 specifications, Hardware preparation and installation

Hardware Preparation and Installation
MVME7100 Single Board Computer Installation and Use (6806800E08D)
29
2.3
Requirements
Make sure that the board, when operated in your particular system configuration, meets the
requirements specified in the next sections.
2.3.1
Environmental Requirements
The following table lists the currently available specifications for the environmental
characteristics of the MVME7100. A complete functional description of the MVME7100
baseboard appears in
Chapter 4, Functional Description
.
Operating temperatures refer to the temperature of the air circulating around the board and not
to the component temperature.
Table 2-2 MVME7100 Specifications
Characteristics
Operating
Nonoperating
Operating temperature
0°C to +55°C (32°F to 131°F) entry air
with forced-air cooling
–40°C to +85° C (-40°F to 185°F)
Temperature change
+/-0.5° C/min according to NEBS
Standard GR-63-CORE
Relative humidity
5% to 90% noncondensing
5% to 90% noncondesning
Vibration
1 G sine sweep, 5-100 Hz, horizontal
and vertical (NEBS1)
Shock
20 G peak (half sine) 11mSec
Free Fall
100 mm (unpackaged) per GR-63-
CORE