5 srom configuration switch (s3), Figure 1-5, Front/rear ethernet option settings – Artesyn MVME6100 Single Board Computer Installation and Use (June 2014) User Manual
Page 27: Srom configuration switch (s3), Hardware preparation and installation

Hardware Preparation and Installation
MVME6100 Single Board Computer Installation and Use (6806800D58H)
27
The following illustration shows jumper setting options for J30. The factory default is shown
where applicable:
Refer to
Front/Rear Ethernet and Transition Module Options Header (J30)
for
connector pin assignments.
1.5.5
SROM Configuration Switch (S3)
A part of the 8-position SMT switch, S3 enables/disables the MV64360 SROM initialization and
all I
2
C EEPROM write protection.
The SROM Init switch is OFF to disable the MV64360 device initialization via the I
2
C SROM. The
switch is ON to enable this sequence.
Figure 1-5
Front/Rear Ethernet Option Settings
4294 0
1
11
21
31
10
20
30
40
Front Ethernet
(Default)
1
11
21
31
10
20
30
40
Rear Ethernet
1
11
21
31
1
2
3
4
Non-Specific Transition Module
(Default)
1
11
21
31
10
20
30
40
PMC I/O TO P2
(Default)
1
11
21
31
10
20
30
40
MVME 712M
Transition Module
1
11
21
31
1
2
3
4
MVME 761
Transition Module
J30 Options