4 diag-service, Table 4-3, Diag-service – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual
Page 42: Commands execution

Commands Execution
ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)
42
Expected Output
The CLI prompt will show the device category that you have selected
.
This command is valid only in CLI.
4.2.4
diag-service
diag-service
command allows to start, stop, restart, and check status of the diagnostics
service.
Syntax for CLI
diag-service operation <restart/start/stop/status>
The following table provides the diag-service command argument.
Table 4-3 diag-service
Argument
Data Type
Description
operation
String
Requested operation to the diagnostics core.
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>diagnostic</Class>
<Name>vee0</Name>
</Object>
<Method>diagService</Method>
<Argument>
<Name>operation</Name>
<Value>{operation String}</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
- ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-F140 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) ViewCheck on ATCA-9405 Installation and Use (May 2014) ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-9405 Installation and Use (November 2014) ViewCheck on ATCA-9405 Installation and Use (September 2014) ViewCheck on PrAMC-7311 Installation and Use (May 2014) ViewCheck on ATCA-7370 Installation and Use (April 2014)