12 set-rate, Table 4-27, Set-rate – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual

Page 74: Commands execution

Advertising
background image

Commands Execution

ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)

74

4.4.12 set-rate

set-rate

command sets the rate of change value for network monitors.

Syntax for CLI
set-rate monitorId <Monitor Id> deviceInstance <Dev Instance> rate

<Rate>

Syntax for XML
<Script>

<InvokeMethod>

<Object>

<Class>deviceCategory</Class>

<Name>vee0-{Dev Cat}</Name>

</Object>

<Method>setRate</Method>

<Argument>

<Name>deviceInstance</Name>

<Value>Dev Instance</Value>

</Argument>

<Argument>

<Name>monitorId</Name>

<Value>Monitor ID</Value>

</Argument>

<Argument>

<Name>rate</Name>

<Value>Rate</Value>

</Argument>

</InvokeMethod>

</Script>]]>]]>

The following table provides the set-rate command arguments.

Table 4-27 set-rate

Argument

Data Type

Description

Monitor ID

Integer

Type the unique ID of the monitor for which rate of
change value is to be set.

Advertising