ATEIS IDA8 User Manual

Page 279

Advertising
background image

Product Features

279

© 2012 ATEÏS

The fields in the grid are described below:

Type

To indicate the communication protocol used, this field is read only.

IP

The IP address of the device be controlled.

Port

The port number of the device be controlled.

Transmit

The command string for controlling the parameter of the target device. When the user selects
the item of menu and press button [Enter] on the panel, this string will send to the target device.

Timeout

Due to the networking quality could be varied in the different environment. For some applications
with low bandwidth or bad quality network, we can set the timeout value to a large number
because it may take more time to communicate with target devices. 3 seconds is the default
value and it is suitable for most cases.

Success

Set this field could show "Success" when the target device informs URC200 TPC the command
string is transferred successfully. This setting is optional, if you need it, please fill the value "06
0D".

Fail

Set this field could show "Fail" when the target device informs URC200 TPC the command string
is transferred failed. This setting is optional, if you need it, please fill the value "10 0D".