Ez zone stand alone to az plus, Upgraded system existing system, Ez zone/auto-zone upgrade 11 – Auto-Zone Control Systems EZ-Zone to Auto-Zone Upgrade Guide (Version 01C) User Manual

Page 11

Advertising
background image

EZ Zone/Auto-Zone

Upgrade

11

EZ Zone Stand Alone to AZ Plus

Zone Air Dampers

Zone Air Dampers

Up to 16 Zone Air Dampers Allowed

Up to 16 Zone Air Dampers Allowed

Supply

Air Temp

Sensor

Supply

Air Temp

Sensor

To HVAC Unit

Control Panel

To HVAC Unit

Control Panel

Master

Controller

Master

Controller

Bypass Air

Damper

Bypass Air

Damper

Static

Pressure

Sensor

Static

Pressure

Sensor

#1

#1

#16

#16

FA

N

CO

OL

1

CO

OL

2

HE

AT

1

HE

AT

2

BY

PA

SS

OP

EN

BY

PA

SS

CL

OS

E

CO

MM

UN

ICA

TIO

N

AL

AR

M

A =

AL

L Z

ON

ES

B =

EA

CH

ZO

NE

C =

HV

AC

UN

IT/

CL

EA

R

D =

AL

AR

MS

# =

ST

EP

/EN

TE

R

*

= D

EC

IM

AL

+

+

+

+

EZ-ZONE

COOL

MODE

04-08-96

03:48PM

FRI

OCCUPIED

NO

ALARMS

2

8

5

0

A

C

B

D

1

7

4

*

3

9

6

#

YO

RK

®

FA

N

CO

OL

1

CO

OL

2

HE

AT

1

HE

AT

2

BY

PA

SS

OP

EN

BY

PA

SS

CL

OS

E

CO

MM

UN

ICA

TIO

N

AL

AR

M

A =

AL

L Z

ON

ES

B =

EA

CH

ZO

NE

C =

HV

AC

UN

IT/

CL

EA

R

D =

AL

AR

MS

# =

ST

EP

/EN

TE

R

*

= D

EC

IM

AL

+

+

+

+

EZ-ZONE

COOL

MODE

04-08-96

03:48PM

FRI

OCCUPIED

NO

ALARMS

2

8

5

0

A

C

B

D

1

7

4

*

3

9

6

#

YO

RK

®

Zone Air Dampers

Zone Air Dampers

Up to 16 Zone Air Dampers Allowed

Up to 16 Zone Air Dampers Allowed

Supply

Air Temp

Sensor

Supply

Air Temp

Sensor

To Other Zone Managers

(Up to 30 Allowed On System)

To HVAC Unit

Control Panel

Network Loop

Network Loop

Local Loop

Zone Manager

Zone Manager

To HVAC Unit

Control Panel

Bypass Air

Damper

Bypass Air

Damper

Static

Pressure

Sensor

Static

Pressure

Sensor

#1

#1

#16

#16

Return

Air Temp

Sensor

Outside

Air Temp

Sensor

Return

Air Temp

Sensor

Only One OA

Sensor Is

Required

For Entire

System

8

9

7

4

5

6

3

2

1

#

0

*

Remote Link

(Optional)

CommLink II

Multiple Loop

W

C

L I

ATTM

ASTE

R

ONTR

O

S,

NC

CO

MM

LINK

II

COMM

LINK

II

L

C

M

M

O

O

O

O

M

D

P

P

E

Computer

(Optional - By Others)

Syc

hron

ous

Data

Link

C

O

N

T

R

O

L

S

SIG

DET

RDY

SND

REC

PWR

Telephone Line

(Required For Remote Link)

FA

N

CO

OL

1

CO

OL

2

HE

AT

1

HE

AT

2

BY

PA

SS

OP

EN

BY

PA

SS

CL

OS

E

CO

MM

UN

ICA

TIO

N

AL

AR

M

A =

AL

L Z

ON

ES

B =

EA

CH

ZO

NE

C =

HV

AC

UN

IT/C

LE

AR

D =

AL

AR

MS

# =

ST

EP

/EN

TE

R

*

= D

EC

IM

AL

+

+

+

+

Meridian

COOL

MODE

04-08-96

03:48PM

FRI

OCCUPIED

NO

ALARMS

2

8

5

0

A

C

B

D

1

7

4

*

3

9

6

#

YO

RK

FA

N

CO

OL

1

CO

OL

2

HE

AT

1

HE

AT

2

BY

PA

SS

OP

EN

BY

PA

SS

CL

OS

E

CO

MM

UN

ICA

TIO

N

AL

AR

M

A =

AL

L Z

ON

ES

B =

EA

CH

ZO

NE

C =

HV

AC

UN

IT/C

LE

AR

D =

AL

AR

MS

# =

ST

EP

/EN

TE

R

*

= D

EC

IM

AL

+

+

+

+

Meridian

COOL

MODE

04-

08-96

03:48PM

FRI

OCCUPIED

NO

ALARMS

2

8

5

0

A

C

B

D

1

7

4

*

3

9

6

#

YO

RK

1
4

2
5

3
6
9

8
0

7

Ent

er

Esc

*

Min

us

Men

u

Cle

ar

De

c.

Ala

rm

Co

mm

un

ica

tio

n

Ov

erri

de

MANAG

ER

MANAGER

SYSTEM

Auto

-Zo

ne

Plu

s

01/01/97

03:38PM

WED

OCCUPIED

NO

ALA

RM

S

System

Manager

(Optional If Computer Front End Used)

Other Controllers

(Optional - Up to 13 On Each Loop))

Upgraded System

Existing System