Troubleshooting – Desa (V)TC36N SERIES User Manual

Page 30

Advertising
background image

www.desatech.com

116192-01B

30

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

POSSIBLE CAUSE

1. Gas leak. See Warning statement

above

1. High or gusting winds

2. Low line pressure

3. Pilot is partially clogged

4. Inner vent pipe leaking exhaust gasses

into system

5. Glass too loose and air tight gasket leaks

in corners after usage

6. Bad thermopile or thermocouple

7. Improper vent cap installation

1. Gas leak. See Warning statement

above

2. Control valve defective

1. Gas leak. See Warning statement

above

1. Air holes at burner inlet blocked

2. Burner flame holes blocked

3. Improper venting or excessive blockage

4. Excessive amounts of embers and pan

material

OBSERVED PROBLEM

Fireplace produces unwanted odors

Fireplace shuts off in use

Gas odor even when control knob is in OFF

position

Gas odor during combustion

Dark residue on logs or inside of fireplace

REMEDY

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 19)

1. Fireplace has been tested for up to

40mph winds. However, extreme condi-

tions may occur. See Lighting Instruc-

tions on page 23

2. Contact local propane/LP or natural gas

company

3. Clean pilot (see Cleaning and Mainte-

nance, page 27)

4. Locate and correct all leaks (see Check-

ing Gas Connections, page 19)

5. Tighten glass

6. Replace faulty component

7. Check for proper installation and free-

dom from debris or blockage

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 19)

2. Replace control valve

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 19)

1. Clean out air holes at burner inlets. Pe-

riodically repeat as needed

2. Remove blockage or replace burner

3. Have the vent system inspected, includ-

ing the termination cap. Remove any

restrictions or obstruction

4. Clear excess embers until a minimum

gap of 1/2" remains under the grate

TROUBLESHOOTING

Advertising