INSTALLATION PLANNING

There are two basic types of direct-vent installation:
• Horizontal Termination
• Vertical Termination

Horizontal Termination Installation

IMPORTANT:

Horizontal square terminations require only in-

ner portion of wall firestop. Horizontal installations using round

termination require exterior portion of wall firestop (see Figure

14, page 10).
1. Set the fireplace in its desired location and determine the route

your horizontal venting will take. Do not secure the fireplace

until all venting has been installed. Some installations require

sliding the fireplace in and out of position to make final venting

connections. Figures 14 through 18 on pages 10 through 12 show

different configurations for venting with horizontal termination

that will help you decide which application best suits your instal-

lation. Check to see if wall studs or roof rafters are in the path of

your desired venting route. If they are, you may want to adjust

the location of the fireplace.

2. Direct vent pipe sections and components are designed with

special twist-lock connections.

Twist-Lock Procedure:

The female ends of the pipes have

locking lugs (indentations). These lugs will slide straight into

matching slots on the male ends of adjacent pipes. Push pipe

sections together and twist one section clockwise approxi-

mately one-quarter turn until the sections are fully locked (see

Figure 8). Note: Horizontal runs of vent must be supported

every three feet. Use wall straps for this purpose.

3. Use a 45° elbow to connect venting system to fireplace flue

collar. The elbow is designed to be twist-locked onto the flue

collar as described in step 2. IMPORTANT: Do not attempt

to alter the configuration of the elbow by cutting, twisting,

bending, etc.

4. Assemble the desired combination of pipe and elbows to the

fireplace flue collar. If there are long portions of venting run,

pre-assembled pipe sections may be installed as subassemblies

for convenience.

5. Carefully determine the location where the vent pipe assembly

will penetrate the outside wall. The center of the hole should

line up with the center-line of the horizontal vent pipe. Mark the

wall for a 10

3

/

4

" x 10

3

/

4

" square hole. Cut and frame the square

hole in the exterior wall where the vent will be terminated. If

the wall being penetrated is constructed of noncombustible

material, such as masonry block or concrete, a 8

1

/

2

" hole with

zero clearance is acceptable (see Figure 9).

VENTING INSTALLATION

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning

Figure 8 - Vent Pipe Connections

Female

Locking

Lugs

Male

Slots

(Framing

Detail)

10

3

/

4

"

(273 mm)

10

3

/

4

" Inside Framing

(273 mm)

10

3

/

4

"

(273 mm)

8

1

/

2

"

(216 mm)

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

Figure 9 - Vent Opening Requirements