6features and specifications, Installation options, Specifications – Avalon Firestyles 1080 CF Installation User Manual

Page 6: Dimensions

Advertising
background image

6

Features and Specifications

© Travis Industries

4090807

100-01193_003

Installation Options

•

Residential or Mobile Home

•

Straight or Corner Placement

•

Flush or Recessed Face

•

Raised or Floor Placement

•

Internal or External Chase

•

Horizontal or Vertical Vent

•

Bedroom Approved

Specifications

Natural Gas

Propane

Maximum BTU Input Per Hour

36,000

36,000

Minimum BTU Input on Low

20,800

23,500

Dimensions

Tabs for lifting handles
(sku 98500711)

Weight: 250 Lbs.

1-1/2" **

* Includes the required 2" clearance.
** Includes the 1-1/2" standoff below the baseplate.
*** Does not include the required 4" clearance to each side.

25"*

49.5"

12-1/4"*

37.5"

32-3/4" **

43" **

Base of Fireplace
(bottom of standoffs)

27" ***

NOTE: 4" Clearance to
the Sides of the Fireplace

NOTE: 2" Clearance to
the Back of the Fireplace

8-5/8" Outside Diameter

41-1/2" **

5"

49-1/2" **

56-3/4" **

2"

Figure 2