Installation, Alcove installation requirements – Avalon Firestyles Cottage User Manual

Page 12

Advertising
background image

12

Installation

(for qualified installers only)

Travis Industries

93508113

4 020325

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered
an alcove installation. Because of the reduced height, the special installation requirements listed
below must be met.

•

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

Minimum Clearance
(See the illustration above)

Co m b u st i b l

e Alcove

N o n -

Combustible

A l c o v e

A

Sidewall to stove

18"

8"

B

Backwall to stove

11-1/2"

3"

D

Connector to sidewall

27-1/4"

17-1/4"

E

Connector to backwall

12-1/2"

4-1/2"

G

Maximum Depth of Alcove

48"

48"

H

Minimum Width of Alcove

61-1/8"

41-1/8"

J

Minimum Height of Alcove

84"

6" Above Stove Top

•

Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have
walls and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete).
This non-combustible material must be spaced and ventilated at least 1" off of all combustible
materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling.
All other alcoves are considered combustible. The clearances below must be met:

Non-combustible alcove

construction (on walls

and ceiling) - see the

explanation above.

3 1/2" thick non-

combustible

material

Combustible materials

1" Min.

Ventilated

air space

Non-combustible

reinforcer

a

b

d

e

h

j

g

Advertising
This manual is related to the following products: