Installa tion, Mobile home requirements – Avalon Firestyles Cottage User Manual

Page 13

Advertising
background image

Installa tion

(for qualified installers only)

13

Travis Industries

93508113

4 020325

Mobile Home Requirements

•

Outside air must be installed - see "Outside Air Requirements" on page 11

•

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance

adapter for the connector being used.

•

Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)

Minimum Clearance
(See the illustration

b e l o w )

Reduced Clearance

C o n n e c t o r

A

Sidewall to stove

18"

B

Backwall to stove

11-1/2"

C

Cornerwall to stove

10"

D

Connector to sidewall

27-1/4"

E

Connector to backwall

12-1/2"

F

Connector to cornerwall

18-1/2"

Straight Installations

a

b

d

Corner Installations

c

f

NOTE:

Measure stove clearances to the stove top.

e

•

If using offsets, use the connector
clearance listed to the right, not the
connector manufacturer's
c l e a r a n c e
.

•

The appliance must be secured to the floor
(not required in all areas - consult your
building official). Secure the outside air
boot to the floor and stove to insure the
stove does not dislocate.

•

The appliance must be grounded to the
chassis of the mobile (not required in all
areas - consult your building official).

•

The appliance must not be located in the
bedroom of a mobile home (not required in
all areas - consult your building official).

12” Min.

Connector Clearance
(as outlined above)

Stove Clearance
(as outlined above)

Advertising