Code 49 – Avery Dennison Monarch 9864 Bar Code Information User Manual

Page 6

Advertising
background image

10/07 Rev. 3.03-01

EASY PLUG MANUAL

Bar Code Information

All Devices

6

MSI

The modified Plessey Code (pulse-width modulated) from MSI Data Corpo-
ration.

Characters

Numeric (0 to 9)

No. of print places

14 characters including checksum

Ratio

none

Checksum

Calculation by Modulo 10

Other

Easy Plug: #YB-14

ITF

ITF stands for Interleaved Two Five, ITF thus corresponds with Code 2/5 in-
terleaved.

Characters

Numeric (0 to 9)

No. of print places

Even-numbered (2, 4, 6,...)

Ratio

1:2.5 (in accordance with specification), size-dependent.

An odd-numbered ratio would require the printing of half dots. This is why
rounding takes place: 1:2.5 => 1:3
In the case of threefold magnification: 3:7.7 => 3:8

Checksum

Calculation by Modulo 10 can be switched on/off

Other

ITF 8: 8 places

ITF 14: 14 places

Code 49

Specification

Uniform Symbology Specification Code 49 (ANSI/AIM-BC6-2000)

Characters

All ASCII characters (128) .

Codable
characters

2 rows: 9 alphanumerical or 15 numerical characters

8 rows: 49 alphanumerical or 81 numerical characters

Easy Plug

Command #CFN

Advertising