Code 49 – Avery Dennison Monarch 9864 Bar Code Information User Manual
Page 6

10/07 Rev. 3.03-01
EASY PLUG MANUAL
Bar Code Information
All Devices
6
MSI
The modified Plessey Code (pulse-width modulated) from MSI Data Corpo-
ration.
Characters
Numeric (0 to 9)
No. of print places
14 characters including checksum
Ratio
none
Checksum
Calculation by Modulo 10
Other
Easy Plug: #YB-14
ITF
ITF stands for Interleaved Two Five, ITF thus corresponds with Code 2/5 in-
terleaved.
Characters
Numeric (0 to 9)
No. of print places
Even-numbered (2, 4, 6,...)
Ratio
•
1:2.5 (in accordance with specification), size-dependent.
•
An odd-numbered ratio would require the printing of half dots. This is why
rounding takes place: 1:2.5 => 1:3
In the case of threefold magnification: 3:7.7 => 3:8
Checksum
Calculation by Modulo 10 can be switched on/off
Other
ITF 8: 8 places
ITF 14: 14 places
Code 49
Specification
Uniform Symbology Specification Code 49 (ANSI/AIM-BC6-2000)
Characters
All ASCII characters (128) .
Codable
characters
•
2 rows: 9 alphanumerical or 15 numerical characters
•
8 rows: 49 alphanumerical or 81 numerical characters
Easy Plug
Command #CFN