Pilot assembly, Adjusting air shutter (venturi), Options – Drolet SIT 0.820.634 Nova User Manual

Page 14: Replacement parts, Pilot assembly adjusting air shutter, Options replacement parts

Advertising
background image

EXCEL-FIRE GAS STOVE

13

Pilot assembly

Adjusting air shutter (Venturi)

The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating
the appliance for half an hour or so the flames should have turned a nice yellow colour. However,
in higher altitudes you may find a smudging up of the glass after a few days. The shutter should
then be adjusted open in 1/16” increments until the glass stays clear. If the flame does not turn
yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you
need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and
the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to
move the shutter.

OPTIONS

ITEM DESCRIPTION

Part no

Wall thermostat kit

AC05558

130 CFM blower kit with variable speed control

AC05914

REPLACEMENT PARTS

ITEM DESCRIPTION

Part no

6’’ stove pipe adapter

SE9348

Set of logs 5

AC05791

Burner (natural gas or propane)

SE09311-01

Pyroceram Glass (19.446" x 11.737")

SE09335-05

1/2 dia. gasket for door

40020

U gasket for glass

40005

Blower 130 cfm

44070

Variable speed control

44080

Thermo-switch (for blower)

44044

Gas valve (natural gas) SIT

49133

Gas valve (propane) SIT

49126

Pilot assembly (natural gas) SIT

49103

Pilot assembly (propane) SIT

49106

Piezo igniter

49128

Burner orifice (natural gas #36)

9071

Burner orifice (propane #52)

9071-01

Thermocouple 49122

Spill switch

44047

Thermopile 49095

Advertising