Burner, Gas valve sit 820 nova mv, Pressure adjustments – Drolet SIT 0.820.634 Nova User Manual

Page 5: Natural gas, Elevation (canada) input rating, Over 2000 ft refer to local codes, Gaz propane, Burner gas valve sit 820 nova mv

Advertising
background image

EXCEL-FIRE GAS STOVE

4

Burner

Naturel Gas

Propane LP

Maximum Input, BTU/h (kW)

minimum :

maximum

:

20 000

(5,9)

30

000

(8,8)

20

000

(5,9)

26

000

(7,6)

Inlet Pressure INWC (kPa)

minimum :

maximum

:

5,0

(1,3)

7,0

(1,8)

11,0

(2,8)

14,0

(3,5)

Manifold Pressure INWC (kPa)

minimum :

maximum

:

1,8

(0,5)

3,5

(0,9)

7,0

(1,8)

10,0

(2,5)

Burner orifice

∅ :

#36 DMS

#52 DMS

Injecteur du pilot

∅ :

#51 DMS

#30 DMS

Air Shutter opening

(in.)

1/4 open

full open

Gas Valve SIT 820 Nova mV

Naturel Gas

Propane LP

Millivolt Gas Valve :

Model SIT 0.820.634 Nova

mV

Model SIT 0.820.633 Nova

mV

Your stove is equipped with a sophisticated gas control valve, which will give you a safe use of your appliance. The
gas control valve SIT 820 Nova mV operates without electricity due to the energy given by the pilot flame and
captured by the thermo-generator. (also called thermopile). The admission of the gas fuel to the burner is done only
under safe conditions.

Pressure Adjustments

Adjustments to the valve assembly must be performed by a qualified service person.

• The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa);

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less that ½ psi (3.5
kPa);

NATURAL GAS

The inlet supply or line pressure must be a minimum of 5 INWC and a maximum of 7 INWC. The orifice has a #36
hole.

ELEVATION (Canada)

INPUT RATING

0-4500 ft (0-1400m)

30 000 BTU/h (8.8 kW)

Over 4500 ft (1400 m) +

30 000 BTU/h (8.8 kW) less 4% per 1000 ft (300 m)

or reduce manifold pressure by 0.25 INWC per 1000 ft (300 m)

ELEVATION (USA)

INPUT RATING

0-2000 ft

30 000 BTU/h (8.8 kW)

Over 2000 ft

Refer to local codes

GAZ PROPANE

The inlet supply or line pressure must be a minimum of 10.5” WC and a maximum of 12” WC. The orifice has a #52
hole.

ELEVATION (Canada) INPUT

RATING

0-4500 pi (0-1400 m)

26 000 BTU/h (7.6kW)

4500 pi (1400m)+

26 000 BTU/h (7.6kW) moins 4% par 1000 pi (300m)

or reduce manifold pressure by 1 INWC per 1000 ft

ELEVATION (USA)

INPUT RATING

0-2000 ft

26 000 BTU/h (7.6kW)

Over 2000 ft

Refer to local codes

NOTE : The input rating should always be checked when first running this appliance. To do this, verify inlet valve
pressure and manifold pressure,. Adjust manifold pressure to meet values range as indicated in burner
characteristics table.