Initialise or activate option
After you have mounted the option correctly to the printer - and the necessary adjustment
the option can be activated
This can be done by changing the parameter in the Firmware.
• switch on the unit
display shows
OFF
• press FEED and CUT at the
display shows
INFO
same time
• press CUT until
display shows
SYSP
•
press
ENTER display
shows
EMUL
• press CUT until
display shows
SENS
•
select
until
display
shows
FULL
• press ENTER to accept
beep
• press FEED and CUT
display shows
SYSP
• press FEED and CUT
display shows
OFF
Attention:
The option is now activated - all other option’s are deactivated!
Check Sensor
The sensor of the full size sensor – used to detect the presence of a label – can be
checked.
Select in the printer menu the function SCHK – go to menu point U xx and test the function
of the sensor.
Without media a shown in the display
‚U 0‘
with
media
is
shown
‚U 15‘