Media limitation, Unpack – Avery Dennison Full Size Sensor User Manual
Page 6

Service Manual Full Size Sensor
11/07
Rev. 1.03
6
Media limitation
Please watch carefully, that the full size sensor can only be used with cardboard material
(notched) ! The sensor is a digital sensor – means only 0 and 1 – self adhesive media can
not be used.
The
minimum media width
– used with the full size sensor – has to be
36 mm
! If the full size
sensor is mounted to the unit – as well the standard sensor can not be used for smaller
material.
The optional full size sensor can be moved from
Printer
can be moved from - to (mm)
TTX 450
16 – 93
TTX 650
16 – 134
TTX 950
16 – 165
Unpack
Normally the full size sensor is supplied mounted to the printer (installed) ! If this is not the
case – the option can be retrofitted by a service technician !
Attention:
To activate the sensor please follow the instruction shown in chapter set up
mode.
Please check if all parts are delivered
2
additional
axle
1
outer
side
plate
1
inner
side
plate
1 steal part inner
1 sensor assy. ( 2 parts – 1 cable)
1 outer media guiding