VENTING INSTALLATION
INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Figure 24 - Vertical Venting Configuration With No Horizontal
Run (Vertical Round High Wind Termination Shown)

Note: Install restrictor
into inner collar of
fireplace as shown.

45

°

Elbow

HIGH ALTITUDE INSTALLATION

Your DESA International direct-vent fireplace has been CSA tested
and approved for elevations from 0-2000 feet (USA) and elevations
from 0-4500 feet (Canada) .

When installing this fireplace at an elevation above 2000 feet (in the
USA), you may need to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your local gas company for
proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in
Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice
for your location.

For assistance with any high altitude installation contact DESA
International’s Customer Service Department at 1-866-672-6040.

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.)

High Altitude Installation

Parts Lists for Venting Kits and Components for V36 and V42 Model Series

PARTS LISTS FOR VENTING KITS AND
COMPONENTS FOR V36 AND V42 MODEL
SERIES

DESA International (5/8") Pipe & Vent Kits

Number Description

01492

Horizontal Square Termination Kit

Includes: 45

°

Elbow (Through 5" Wall), Wall Firestop,

Horizontal Square Termination

01493

Basic Vertical Termination Kit

Includes: Vertical Termination, Adjustable Flashing,
Storm Collar

01491

Horizontal Round Termination Kit

Includes: Round Termination, Wall Firestop, and
45

°

Elbow (Through 5" Wall)

01497

12" Section Coaxial Pipe - Galvanized (4)

01498

18" Section Coaxial Pipe - Galvanized (4)

01499

24" Section Coaxial Pipe - Galvanized (4)

01500

36" Section Coaxial Pipe - Galvanized (4)

01501

48" Section Coaxial Pipe - Galvanized (4)

01513

6" Section Coaxial Pipe - Galvanized (4)

01606

Adjustable 17"-24" Section Coaxial Pipe -

Galvanized (4)

F8030

Adjustable 7"-12" Section Coaxial Pipe - Galvanized (6)

D1032

Adjustable 7"-12" Section Coaxial Pipe - Galvanized (1)

DESA International Elbows

Number Description

01502

45

°

Elbow - Galvanized (4)

01503

90

°

Elbow - Galvanized (4)