Service procedures, Continued – Desa GK30 User Manual

Page 12

Advertising
background image

108954

10

AIR OUTPUT, AIR INTAKE, AND LINT
FILTERS

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using 5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see Preventative Maintenance
Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters

PUMP PRESSURE ADJUSTMENT

1.

Remove pressure gauge plug and plastic cap (GK20 only) from
filter end cover.

2.

Install accessory pressure gauge (part number HA1180).

3.

Start heater (see Operation, page 5). Allow motor to reach full
speed.

4.

Adjust pressure. Turn relief valve to right to increase pressure.
Turn relief valve to left to decrease pressure. See specifica-
tions below for correct pressure for each model.

5,

Remove pressure gauge. Replace pressure gauge plug and plas-
tic cap (GK20 only) in filter end cover.

Figure 13 - Air Output, Air Intake, and Lint Filters, Model GK20

SERVICE PROCEDURES

Continued

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Air Intake
Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, Model GK30

Fan
Guard

Figure 15 - Pressure Gauge Plug and Plastic Cap Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 16 - Adjusting Pump Pressure

Pump
Pressure

Model

(PSI/Bar)

GK20

4.9/0.338

GK30

4.9/0.338

Relief
Valve

Plastic Cap

SERVICE PROCEDURES

Advertising
This manual is related to the following products: