6

PREVENTATIVE
MAINTENANCE SCHEDULE

How To

See Storing, Transporting, or Shipping, page 5

See Air Output, Air Intake, and Lint Filters, page 10

See Air Output, Air Intake, and Lint Filters, page 10

See Fuel Filter, page 8

See Fan, page 13

WARNING: Never service heater while it is plugged

in, operating, or hot. Severe burns and electrical
shock can occur.

Item

Fuel tank

Air output and lint filters

Air intake filter

Fuel filter

Ignitor

Fan blades

Motor

How Often

Flush every 150-200 hours of operation or
as needed

Replace every 500 hours of operation or
once a year

Wash and dry with soap and water every
500 hours of operation or as needed

Clean twice a heating season or as needed

No maintenance required

Clean every season or as needed

Not required/permanently lubricated

REMEDY

1. Check all electrical connections. See

Wiring Diagram, page 14

2. If fan does not turn freely, see Pump

Rotor, page 12

3. Replace ignition control assembly
4. Replace motor

POSSIBLE CAUSE

1. Bad electrical connection between motor

and ignition control assembly or ignition
control assembly and power cord

2. Binding pump rotor

3. Defective ignition control assembly
4. Defective motor

TROUBLESHOOTING

WARNING: Never service heater while it is plugged

in, operating, or hot. Severe burns and electrical
shock can occur.

WARNING: High voltage!

FAULT CONDITION

Motor does not start five seconds after
heater is plugged in (ON/OFF switch light
remains on)

ATTENTION:

The ignition control has built-in protection against

current overloads. Use the light in the ON/OFF switch to trouble-
shoot the fault condition.