Technical data – BECKHOFF KL2612 User Manual

Page 3

Advertising
background image

Datasheet for KL2612, Version 1.1

Beckhoff™ and TwinCAT are registered trademarks of Beckhoff. Information is subject to change without notice and warranted only to the extent agreed in the terms
of contract. Beckhoff Automation GmbH, Eiserstr. 5, 33415 Verl, Germany, Phone: +49 (0) 5246 963 0, Fax.: +49 (0) 5246 963 149,

http://www.beckhoff.com


Technical data

Technical data

KL2612

Number of outputs

2 x change-over

Contact material

Gold-clad silver alloy

Switched voltage max.

125 V AC / 30 V DC

Switched current max.

5 A

Switched power max.

with resistive load

alternating voltage

0,5 A

125V AC

direct voltage

2 A

30V DC

Minimum permitted load

(approximate)

10

µ

A at 10mV

Reaction times

at rated load

Max. reaction time

4 ms

Max. release time

4 ms

max. bounce time

4 ms

Electrical isolation

500 V

eff

(K-bus/mains voltage)

K-bus current consumption

60 mA

Bit width in the process

image

2 A

Service life (operating

cycles) mechanical

10

8

cycles

Operating cycles electr.

(min.)

10

5

resistive load switches

at 30 V DC, 2 A

or 125 V AC, 0,5 A

Permitted operating

frequency at maximum

contact load

20 cycles / min

Contact resistance max. (new)

< 40 mOhm

Insulation resistance (min).

100 MOhm at 500 V DC

Test voltage between

open contacts

750 V (1 min. between open contacts)

Configuration

No address or configuration settings

Weight approx.

80 g

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Relative humidity

95% without dew formation

Vibrations/Shock

resistance

according to IEC 68-2-6 / IEC 68-2-27

EMC resistance burst / ESD

According to EN 50082 (ESD, burst) / EN 50081

Installation position

any

Type of protection

IP20


Advertising