If you want to use the position control of the servo amplifier, then you must enter the specific

parameters for your drive:

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

ò

Axis type :

- Click on the POSITION button
- Click on the POSITION DATA button
- Select the axis type (linear or rotary)

Resolution :

- Enter the denominator and numerator for the resolution. Here you adjust the path

traversed by the load in positioning units (length unit for linear axes, or °mech.
for rotary axes) to match the number of turns of the motor.
Only integer entries are permitted.

Example 1: Ratio = 3.333 mm / turn

=> resolution = 10000/3 µm/turn (all other path entries in µm)

or

=> resolution = 10/3 mm/turn (all other path entries in mm)

Example 2: Ratio = 180 °mech./turn

=> resolution = 180/1 °mech./turn (all other path entries in °mech)

vmax :

- Enter the maximum traversing speed for the load that results from the resolution

at the rated speed of the motor. The dimensional unit is derived from the
resolution (°mech./sec or length units/sec).

Example 1: resolution = 10000/3 µm/turn, n

nom

= 3000 turns/min

=> vmax = resolution * n

nom

= 10000/3 * 3000 µm/min = 10 000 000 µm/min

or

=> vmax = resolution * n

nom

= 10/3 * 3000 mm/min = 10 000 mm/min

Example 2: resolution = 180 °mech/turn, n

nom

= 3000 turns/min

=> vmax = resolution * n

nom

= 180 * 3000 °mech/min = 9000 °mech/s

t_acc/dec_min :

- Enter the time in ms that the drive requires, with the

mechanically permissible maximum acceleration,
to accelerate from zero speed to vmax.

InPosition :

- Enter the window for InPosition. This value is used for the InPosition message.

The dimensional unit is derived from the resolution
(°mech. or length unit).

Typical value : e.g. approx. resolution * 1/100 turn

- Clicken on APPLY and then on OK
-
Answer the query “Save to EEPROM/Reset” with NO

(the data are in the RAM and will be permanently stored later)

max. following error :

- You now see the screen page POSITION
- Enter the window for the following error. This value is used for the message

FOLLOWING ERROR. The dimensional unit is derived from the resolution
(°mech. or length unit).

Typical value : e.g. approx. resolution * 1/10 turn

Save parameters :

- Click on the

button

- Answer the query RESET AMPLIFIER with YES

Quick Start