2 connection of motors with pre-assembled cables, Connection of mo‐ tors with pre‐assembled cables, 2 connection of motors with pre­assembled cables – BECKHOFF AM8100 User Manual

Page 22

Advertising
background image

Electrical installation

8.2

Connection of motors with pre­assembled cables

Beckhoff offers preassembled motor and feedback cables for safe, faster and flawless installation of the
motors. Beckhoff cables have been tested with regard to the materials, shielding and connectors used. They
ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other
cables may lead to unexpected interference and invalidate the warranty.

• Carry out the wiring in accordance with the valid standards and regulations.

• Only use our preassembled shielded cables for the power and feedback Connections.

Connect up the shielding according to the wiring diagrams in section Shielding concept

[

}

 24].Incorrectly installed shielding inevitably leads to EMC interference.

Detailed specifications of the cables are listed on our homepage
Download→Documentation→Drive Technology→Cable.

8.2.1

EL72xx­0010 Connection diagram for 8100 Motors with OCT

Motor cable ZK4704­0421­2000

Synchronous servomotor AM8100

22

Version 1.1

Advertising