Venting installation – Desa (V)G42/50 User Manual

Page 10

Advertising
background image

www.desatech.com

109493-01N

10

VenTing insTallaTion

Continued

Nail Only
Outer
Perimeter
of Flashing

Storm
Collar

Flashing
Cone

Underlap
Shingles
at Bottom

Overlap
Shingles Top
and Sides Only

Figure 13 - Flashing Installation

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, it is

required that putty tape be used between the flash-

ing and the roof. The flashing must be secured to

the roof using #8 x 3/4" screws and then sealed

with roof coating to prevent leakage through the

screw holes. A roof coating must also be applied

around the perimeter of the flashing to provide a

proper seal.
Storm Collar Installation (SC2-1)

Place storm collar over pipe and slide down until

it is snug against the open edge of the flashing (see

Figure 14). Apply waterproof caulk around the

perimeter of the collar to provide a proper seal.

Figure 14 - Storm Collar

Chimney
Pipe

Waterproof
Caulk

Storm
Collar

Flashing

Terminations/Spark Arrestor

The fireplace system must be terminated with the

listed round top or chase terminations. In any case,

refer to the installation instructions supplied with

the termination.

Secure
Termination
to Outer
Pipe with 3
Screws

RTL-10D

Level of
Flue Gas
Outlet

Stainless
Inner Flue
Pipe

Waterproof
Caulking

Storm
Collar

Flashing

Underlap
Shingles

Figure 15 - Termination

Overlap
Shingles (Top and Sides
of Flashing Base)

CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions

provided with the termination

being used.

CHASE INSTALLATIONS

Instructions for chase installations are included

with the chase style termination chosen. In a mul-

tiple chase installation, be sure to provide adequate

distance between terminations to prevent smoke

spillage from one termination to another. Termi-

nations be separated a minimum of 24" center to

center and stacked at a minimum vertical height

difference of 18" (see Figure 16).
Note:

If a decorative shroud is to be installed,

contact the manufacturer for specifications.

4" Min.

4" Min.

18"

Min.
Typ.

Figure 16 - Multiple Chase Installation