Fault-tolerance features, Table 8, Raid level migration – Dell POWEREDGE RADI H800 User Manual

Page 16

Advertising
background image

Dell

DELL PERC H700 and H800 Technical Guide

16

Table 8. RAID Level Migration

Source RAID
Level

Target RAID
Level

# of Physical
Drives
(Beginning)

# of Physical
Drives (End)

Capacity
Expansion
Possible

Description

RAID 0

RAID 1

1

2

No

Converting non-
redundant virtual disk
into a mirrored virtual
disk by adding one drive.

RAID 0

RAID 5

1 or more

3 or more

Yes

At least one drive needs
to be added for
distributed parity data.

RAID 0

RAID 6

1 or more

4 or more

Yes

At least two drives need
to be added for dual
distributed parity data.

RAID 1

RAID 0

2

2 or more

Yes

Removes redundancy
while increasing
capacity.

RAID 1

RAID 5

2

3 or more

Yes

Maintains redundancy
while doubling capacity.

RAID 1

RAID 6

2

4 or more

Yes

Two drives are required
to be added for
distributed parity data.

RAID 5

RAID 0

3 or more

3 or more

Yes

Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.

RAID 5

RAID 6

3 or more

4 or more

Yes

At least one drive needs
to be added for dual
distributed parity data.

RAID 6

RAID 0

4 or more

4 or more

Yes

Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.

RAID 6

RAID 5

4 or more

4 or more

Yes

Removing one set of
parity data and
reclaiming disk space
used for it.

4.5

Fault-Tolerance Features

Below is a list of features that provide fault tolerance to prevent data loss:

Non-volatile cache: extends data retention from hours to years

Support for SMART

Redundant path support (for PERC H800 only)

Physical disk failure detection

Advertising
This manual is related to the following products: