Technical specifi cations – Beurer GS 80 User Manual

Page 11

Advertising
background image

11

Possible faults

Solution

Radio connection between scale and out-
door sensor interrupted.

Reinsert the batteries in the scale and outdoor sensor;
the scale emits an acoustic signal when the batteries are
inserted.
Ensure a suffi

cient distance from the following electromag-

netic sources: electricity pylons, TV or computer radio sys-
tems, fi tness devices, mobile telephones, weather stations.

The outdoor sensor is too far from the scale.

Reduce the distance between the scale and outdoor sensor
to a maximum of 30 meters (open fi eld).

The batteries in the scale are empty.

Replace the batteries in the scale (see page 9).

The batteries in the outdoor sensor are
empty.

No weather forecast is displayed. Replace the batteries in
the outdoor sensor.

We hereby guarantee that this product complies with the European R&TTE Directive 1999/5/EC.
Please contact the specifi ed service address to obtain further information, such as the CE Declaration of
Conformity.

11. Technical specifi cations

Measurement range

2 – 150 kg, 100 g graduation

Inside temperature

-10 °C – +50 °C

Outside temperature

-50 °C – +70 °C

Temperature graduation

0.1 °C

Radio transmission

433 MHz

Range

30 metres (open fi eld)

Inside temperature

30 second measurement interval

Outside temperature

57 second measurement interval

Advertising