Hans Rudolph
Fixed Orifice Pneumotachs

Fixed-orifice pneumotachs for use with the RSS 100 Research
Pneumotach system.

Adult Flow Sensor
Range

1.0 to 180 L/min

Accuracy

+/- 3% of reading

Resolution

0.1 L/min

Neonatal Flow Sensor
Range

0.24 to 40 L/min

Accuracy

+/- 3% of reading

Resolution

0.01 L/min

Order code
171109
Adult Fixed-Orifice pneumotach
171110 Neonatal Fixed-Orifice pneumotach

Hans Rudolph Linear Pneumotachs

Specifically designed, patented and manufactured for Physiological
and Respiratory testing, the Hans Rudolph linear pneumotachs
utilise a unique housing configuration and screen assembly design
to convert the flow of gas in either direction into a proportional linear
signal of differential pressure from the two pressure taps for input into
a differential gas pressure transducer. Models are available with the
appropriate parameters, such as Volume Dead Space, Linear Flow
Range and Large/Small Flange Port tube size connection.
All models are available as Heated and Non-Heated Pneumotachs
and are supplied with an individual calibration record.

Order codes
3830

Adult heated pneumotach (0-400 L/min)

4830

Adult non-heated pneumotach (0-400 L/min)

3813

Adult exercise heated pneumotach (0-800 L/min)

4813

Adult exercise non-heated pneumotach (0-800 L/min)

Many other models available

Hans Rudolph Heater Controls

Proportional solid state heater control accurately regulate temperature.

Order codes

3850AF Heater control for one pneumotach (230v - 50Hz)
3850BF Heater control for two pneumotachs (230v - 50Hz)

Hans Rudolph Pneumotach
Amplifier series 1110

Provides the instrumentation necessary to produce an analogue
output proportional to flow when connected to any Hans Rudolph
linear pneumotach. It will also provide an analogue output of an
independent auxiliary pressure signal for measurement of pressure
anywhere in the circuit.

Features
• Flow Ranges from 0-3, 0-5, 0-10, 0-35, 0-100, 0-160,

0-400 and 0-800 litres per minute

• Zero and gain adjustment pots for both outputs
• LED Flow direction indicator

Order codes

1110A Pneumotach amplifier +/- 70cmH

2

O range

1110B Pneumotach amplifier +/- 140cmH

2

O range

Hans Rudolph Research
Pneumotach RSS100

The RSS100 and RSS100/HR research systems measure gas
flow using the differential pressure method. As gas flows through
the pneumotach, the microprocessor based system converts the
measured differential pressure to volumetric flow rate. Flow and
pressure measurements are used to calculate several ventilatory
parameters such as respiratory rate, lung compliance, tidal volume,
minute volume, positive end expiratory pressure, etc.

Features

• Custom Windows software for displaying, storing and

reviewing data

• Embedded microprocessor calculates flow rates and

provides correction for gas density, viscosity, temperature,
barometric pressure and airway pressure

• Flow Ranges from 0-3, 0-5, 0-10, 0-35, 0-100, 0-160, 0-400

and 0-800 litres per minute

The RSS100/HR is for use with linear pneumotachs. Please
order the appropriate Hans Rudolph heated or non-heated linear
pneumotach and heater control unit.
The RSS100 is for use with adult and neonatal fixed-orifice
pneumotachs.

One of each size is supplied with the module.
Additional quantities sold separately.

Order codes
RSS100

Research pneumotach system

RSS100/HR

Research pneumotach system