0 introduction – Drolet GTX-I User Manual

Page 3

Advertising
background image

3

1.0 INTRODUCTION


1.1 Specifications



TABLE 1

ITEM

NATURAL GAS (NG)

PROPANE (LPG)

INPUT: Hi

32,500 Btu/hr (9.5 kW)

27,000 Btu/hr (7.9 kW)

INPUT: Lo

22,500 Btu/hr (6.6 kW)

21,000 Btu/hr (6.2 kW)

MANIFOLD PRESSURE: Hi

3.5” w.c. (0.82kPa) 10.0”

w.c.

(2.49kPa)

MANIFOLD PRESSURE: Lo

1.7” w.c. (0.42kPa)

6.3” w.c. (1.37kPa)

Minimum: 5.0” w.c. (1.25 kPa)

Minimum: 11” w.c. (2.74 kPa)

GAS INLET SUPPLY
PRESSURE:

Maximum: 10.5” w.c. (1.74 kPa)

Maximum: 13” w.c. (3.24 kPa)

ORIFICE SIZE: @ 0-4500’

2 x #57 DMS (2 x 0.043”)

7/64“ (0.109”)

AIR SHUTTER OPENING

*Completely open

Completely open*

CONTROL VALVE TYPE:

Honeywell or SIT 820 Nova

Honeywell or SIT 820

VENTING

Simpson Dura-Vent and

Security Secure Vent

Simpson Dura-Vent and

Security Secure Vent

Combustion efficiency (fan off)
on maximum

70.7% 68.7%

Combustion efficiency (fan on)
on maximum

73.3% 72.3%

FAN

Variable Speed (120v / 60hz)

Variable Speed (120v / 60hz)


*May vary (±25%) depending on the installations. Judgment of installer is required.

REGISTER YOU WARRANTY ONLINE

To receive full warranty coverage, you
will need to show evidence of the date

you purchased your stove. Keep your

sales invoice. We also recommend that

you register your warranty online at

www.drolet.ca

Registering your warranty online will

help us track rapidly the information we

need on your stove.

This heating unit must serve as a supplementary heat source. An alternative heat source should be available in the home
if needed. The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative
heat source.

It is highly recommended that the user buys this product from a retailer who can provide installation and maintenance
advices.

Advertising