12.3 Paging access switches not working correctly

The CX163 leaves the factory configured to bypass the microphone access contacts for all
three zone outputs, so that when the product arrives, all inputs are enabled in all zones.
Internal jumpers J1 to J3 bypass access contacts for Zones 1, 2 and Utility respectively. To
enable the access contact for a particular zone, remove the link on the corresponding jumper.

NOTE: We advise that when you remove a jumper you leave it connected to one pin of the
header so it remains with the apparatus for future use.

12.4 Connecting RSL remotes to the CX163

The CX163 does not support remote source selection so is incompatible with the RSL remote
series. The only remote wallplate supported by the CX163 is the RL-1 remote level plate.