Cb 1 series, Administrator guide – Code Blue CB 1-E ECONOMICAL HELP POINT User Manual
Page 27

Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-157-E
page 27 of 71
CB 1 Series
Administrator Guide
5.0 WIRING (refer to additional wiring instructions for the DFB 1-s and DFB 1-d)
5.1
Ground – The ground (green) wire should be stripped and fastened to the supplied grounding
lug.
5.2
24V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incoming
power wires and fasten them to the terminal screws labeled “Line” and “Neutral.”
5.3
120V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incoming
power wires and fasten tem to the terminals as labeled on the transformer. After completing
the wire connections, install the supplied terminal covers.
All wiring must be installed and connected by experienced and certified personnel to meet
local and national electrical codes, and will include a service disconnect.
Figure 1