Operating heater, Continued, Manual lighting procedure – Desa CLD3924PTA User Manual

Page 18

Advertising
background image

107068-01D

For more information, visit www.desatech.com

For more information, visit www.desatech.com

18

OPERATING HEATER Thermostatically-Controlled Models

Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Thermostat Control Operation
Manual Lighting Procedure

OPERATING HEATER

Continued

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

5.

Turn control knob counterclockwise

C-clockwise

to the PILOT

position. Press in control knob for five (5) seconds (see Fig-
ure 27).

Note:

You may be running this heater for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop out when released, contact

a qualified service person or gas supplier for repairs.

6.

With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service

person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure
.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. This heater

has a safety interlock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

to desired

heating level. The burners should light. Set control knob to
any heat level between HI and LO.

LO

HI

OFF

Pilot

Figure 27 - Control Knob and Ignitor Button Location

Figure 28 - Pilot

Control Knob

Ignitor Button

Thermocouple

Ignitor Electrode

Pilot Burner

Ignitor Electrode

Pilot
Burner

TO TURN OFF GAS

TO APPLIANCE

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level
between HI and LO. The thermostat will gradually modulate
the heat output and flame height from higher to lower settings,
or pilot, in order to maintain the comfort level you select. The
ideal comfort setting will vary by household depending upon the
amount of space to be heated, the output of the central heating
system, etc.

Note:

Selecting the HI setting with the control knob will cause the

burner to remain fully on, without modulating down in most cases.

1.

Follow steps 1 through 5 under Lighting Instructions, pages
17 and 18.

2.

Depress control knob and light pilot with match.

3.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
step 8 under Lighting Instructions
, column 1.

MANUAL LIGHTING

PROCEDURE

Propane/LP

Natural Gas

Shutting Off Heater

Turn control knob clockwise

Clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise

Clockwise

to the PILOT position.

Advertising