SUMMARY OF
SPECIFICATIONS
Equipment Type
T1/E1 G.703 Interface Converter
Modems Supported
Comtech EFData CDM-550 and
CDM-550T Digital Satellite Modems
Operating Modes
E1 (2048 kbps) balanced (120 ohms) and unbalanced (75 ohms)
T1 (1544 kbps) unbalanced (100 ohms)
Per ITU Recommendation G.703
Jitter and Wander
Per ITU Recommendations G.823 and G.824
Power requirements
2.0 Watts maximum
+12 volts DC
-12 volts DC
(Power is supplied by the Modem. These power supplies are
electronically fused and protected.)
Approvals
‘CE’ as follows:
EN 55022 Class B (Emissions)
EN 50082-1 (Immunity)
EN 60950 (Safety)
FCC Part 15 Class B