3 spod ps 2 ‘j3 | power in’ (dc power main) – Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 41

Advertising
background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

System Connections, Installation and Startup

Revision 1

2–7

2.3.4.3

SPOD PS 2 ‘J3 | POWER IN’ (DC Power Main)

The mating connector specification and the pin assignments (Table 2-6)

unique to the SPOD PS 2 DC power interface are as follows:

Mating Connector: CEFD P/N CN/CA3106E2222SB (ITT Cannon CA3106E22-

22SB).

Table 2-6. SPOD PS 2 ‘J3 | POWER IN’ Pin Assignments

Pin

SPOD PS 2 Assignment

A

V+

B

NO CONNECT

C

NO CONNECT

D

V-

2.3.4.4

SPOD PS 2 ‘J3 | POWER IN’ 48VDC Power Main Option

The connector type and mating connector specification and the pin assignments (Table 2-7)

unique to the SPOD PS 2 48 VDC power interface option are as follows:

Unit Connector Type: CEFD P/N CN-0000288 (ITT Cannon CA3102E20-15SB-F80A232).

Supplied Mating Connector: CEFD P/N CN-0000289 (ITT Cannon CA3106E20-15SB-F80A232).

Table 2-7. SPOD PS 2 ‘J3 | POWER IN’ 48VDC Pin Assignments

Pin

SPOD PS 2 Assignment

A

V+

B

V+

C

NO CONNECT

D

NO CONNECT

E

V-

F

V-

G

GROUND (Note 2)

Notes:

1) Use 12 AWG wire to each of the appropriate pins, according to the

individual pin assignments.

2) As an alternative, make the ground connection to the unit's external

ground stud.