When installing into a masonry chimney, it is recommended that the exhaust vent be extended to the top of 
the chimney as shown to the lower right. However, if the vent pipe does not extend to the top of the 
chimney, the pipe must extend a minimum of 18” above the damper. 
You must seal the damper area with a steel plate when using the direct connection method.
The Vent Pipe Must Extend Above The Damper into the first tile of the flue liner (Figure 25) in the USA and 
to the top of the chimney CANADA (Figure 26). The chimney must not be corroded or damaged in any way 
for this type of installation to be permitted. A direct vent may be made through the chimney structure if local 
codes permit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Figure 25 
Figure 26
Metal 
Sealing Plate
18” min.
length
18”
18”
18”
8”
Note: This installation
allowed in Canada
not
DIRECT CONNECTION
6”
Liner Support
Deluxe Cap
Optional
Metal Plate
6”
18”
8”
FULL CHIMNEY RELINE
Note: This installation recommended
for all chimney installations!
is