Comtech EF Data DMD2401/DMD2401L User Manual

Page 153

Advertising
background image

Electrical Interfaces

DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem

5-14

TM065 – Rev. 3.3

5.5.10 IBS ALARMS (J14)


The IBS Alarms Interface Port (J14) is a 25-Pin Female “D” Connector. Refer to Table 5-12 for
connector pinouts.

Table 5-12. IBS Alarms Interface - 25-Pin Female “D” (J14)

Pin Number

Signal

Description

Direction

1

GND

Ground

–

2

IBS Prompt 1NO

Prompt Alarm Out-1 NO

Output

3

NC

Not Connected

–

4

IBS Service 2NO

Service Alarm Out-2 NO

Output

5

NC

Not Connected

–

6

–

Not Used

–

7

GND

Ground

–

8

–

Not Used

–

9

NC

No Connection

–

10

–*

Not Used

–

11

–*

Not Used

–

12

NC

No Connection

–

13

NC

No Connection

–

14

IBS Prompt 1C

Prompt Alarm Out-1 C

Output

15

IBS Prompt 1NC

Prompt Alarm Out-1 NC

Output

16

IBS Service 2C

Service Alarm Out- 2 C

Output

17

IBS Service 2NC

Service Alarm Out- 2 NC

Output

18

–

Not Used

–

19

–

Not Used

–

20

–

Not Used

–

21

–*

Not Used

–

22

ESCBWI 1*

Backward Alarm In- 1

Input

23

–

Not Used

–

24

NC

No Connected

–

25

NC

No Connected

–

* Internally pulled up 5 V on these pins. Do not use as a power supply.