Command/response pairs, Utility commands, Time – Comtech EF Data DT-4500 Series User Manual
Page 81: Date, Physical address, Baud rate, B.6 c, B.6.1 u, B.6.1.1 t, B.6.1.2 d

DT4500 Series Down Converters
MN/DT4500.IOM
Remote Control
Revision 1
63
B.6 C
OMMAND
/R
ESPONSE
P
AIRS
B.6.1 U
TILITY
C
OMMANDS
B.6.1.1 T
IME
Command
Details
Set Time:
<DEV/TIM_hh:mm:ss'cr'
hh = Hour*
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
mm = Minutes ss = Seconds
Retrieve Time:
<DEV/TIM_'cr'
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
* 24 hour military time is used.
B.6.1.2 D
ATE
Command
Details
Set Date:
<DEV/DAT_mm/dd/yy'cr'
mm = Month
Confirmation:
>DEV/DAT_mm/dd/yy'cr'lf']
dd = Day
yy = Year
Retrieve Date:
<DEV/DAT_'cr'
Confirmation: >DEV/DAT_mm/dd/yy'cr''lf']
B.6.1.3 P
HYSICAL
A
DDRESS
The default Physical Address from is 1.
Command
Details
Set Physical Address:
<DEV/SPA_xxx'cr'
xxx = 1 to 255
Confirmation: >DEV/SPA_xxx'cr''lf']
Retrieve Phys. Addr:
<DEV/SPA_'cr'
Confirmation: >DEV/SPA_xxx'cr''lf']
B.6.1.4 B
AUD
R
ATE
The default baud rate is 9600.
Command
Details
Set Baud Rate:
<DEV/SBR_xxxx'cr'
xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4
Confirmation: >DEV/SBR_xxxx'cr''lf']
Retrieve Baud Rate:
<DEV/SBR_xxxx'cr'
Confirmation: >DEV/SBR_xxxx'cr''lf']