Owner’s manual, Inspecting burner – Desa VMH10TPA User Manual

Page 19

Advertising
background image

19

104407

OWNER’S MANUAL

INSPECTING
BURNER

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pat-
tern. Figure 32 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the fireplace will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 32

• turn fireplace off (see To Turn Off Gas to

Appliance, page 18)

• see Troubleshooting, pages 20 through 22

Thermocouple

Pilot Burner

Figure 32 - Incorrect Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)

BURNER FLAME PATTERN

Figure 33 shows a correct burner flame
pattern. Figure 34 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows the flame consistently higher
than one inch above the log.

If burner flame pattern is incorrect, as shown
in Figure 34

• turn fireplace off (see To Turn Off Gas to

Appliance, page 18)

• see Troubleshooting, pages 20 through 22

Figure 33 - Correct Burner Flame Pattern

Figure 34 - Incorrect Burner Flame Pattern

Top of Flame Consistently About
One Inch Higher Than Logs

Top of Flame About
One Inch Below Logs

Advertising