Vmh10tpa, Vent-free propane/lp gas compact fireplace, Specifications replacement parts – Desa VMH10TPA User Manual

Page 26: Parts under warranty, Parts not under warranty

Advertising
background image

26

104407

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

VMH10TPA

®

SPECIFICATIONS

REPLACEMENT
PARTS

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-800-323-5190 for
referral information.

When calling DESA International, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.

When calling DESA International, have ready

• model number of your fireplace

• the replacement part number

Input Rate

10,000 Btu/Hr

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8.5" W.C.

Inlet Gas Pressure (in. of water)*

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

Fireplace (including hood and screws)

25

7

/

8

x 26

13

/

16

x 9

3

/

8

Carton

32

5

/

8

x 27

3

/

16

x 11

5

/

8

Weight, pounds

Fireplace

44

1

/

2

lbs.

Shipping

48 lbs.

* For purposes of input adjustment