Vent-free propane/lp gas compact fireplace, Cgcftp, Inspecting burner – Desa CGCFTP 14 User Manual

Page 18: Operating fireplace

Advertising
background image

18

107036

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

CGCFTP

INSPECTING
BURNER

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern

Figure 32 - Incorrect Pilot Flame Pattern

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pat-
tern. Figure 32 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not properly heating the thermocouple. This
will cause the thermocouple to cool. When
the thermocouple cools, the fireplace will
shut down.

If pilot flame pattern is incorrect, as shown
in Figure 32

• turn fireplace off (see To Turn Off Gas to

Appliance)

• see Troubleshooting, pages 19 through 21

TO TURN OFF GAS

TO APPLIANCE

The thermostatic control used on this fire-
place differs from standard thermostats.
Standard thermostats simply turn on and
off the burner. The thermostat used on
this fireplace senses the room tempera-
ture. The thermostat adjusts the amount
of gas flow to the burner. This increases or
decreases the burner flame height. At times
the er will cycle back on when room tem-
perature drops below the set temperature.

The control knob can be set to any heat
level between HI and LO.

Note:

The thermostat sensing bulb mea-

sures the temperature of air near the fire-
place cabinet. This may not always agree
with room temperature (depending on
housing construction, installation location,
room size, open air temperatures, etc.).
Frequent use of your fireplace will let you
determine your own comfort levels.

OPERATING
FIREPLACE

Continued

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 17.

2.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 under Lighting Instruc-
tions
, page 17.

Shutting Off Fireplace

1.

Turn control knob clockwise

Clockwise

to the OFF position.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

Clockwise

to

the PILOT position.

THERMOSTAT

CONTROL

OPERATION

MANUAL LIGHTING

PROCEDURE

Thermocouple

Pilot Burner

Figure 33 - Correct Burner Flame Pattern

Figure 34 - Incorrect Burner Flame Pattern

BURNER FLAME PATTERN

Figure 33 shows a correct burner flame
pattern. Figure 34 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows sporadic, irregular flame tip-
ping. The flame should not be dark or have
an orange/reddish tinge.

Note:

When using the fireplace the first

time, the flame will be orange for approxi-
mately one hour until the log cures.

If burner flame pattern is incorrect, as shown
in Figure 34

• turn fireplace off (see To Turn Off Gas to

Appliance)

• see Troubleshooting, pages 19 through 21

Advertising
This manual is related to the following products: