Troubleshooting, Troubleshooting -12, 9 troubleshooting – Daktronics AF-3112-34-R,A User Manual

Page 48: Symptom/condition possible cause/remedy

Advertising
background image

Maintenance and Troubleshooting

4-12

4.9 Troubleshooting

This sub-section contains some symptoms that may be encountered in the displays.
This list does not include every possible symptom, but does represent common
situations that may occur.

Symptom/Condition

Possible Cause/Remedy

One or more LEDs on a single module
fail to light.

•

Replace/check ribbon cables on the module.

•

Replace the module.

One or more LEDs on a single module
fail to turn off.

•

Replace/check ribbon cables on module.

•

Replace the module.

A section of the display is not working.
The section extends all the way to the
right side of the display.

•

Replace/check the ribbon cable to the first
module.

•

Check that the first module has power.

•

Replace the first module/driver on the left side
of the first module that is not working.

•

Replace the second module that is not
working.

•

Replace the power supply assembly on the
first module that is not working.

One row of modules does not work or is
garbled.

•

Replace/check ribbon cable to first module.

•

Check for bent pins on module and controller.

•

Replace controller.

•

Replace first module.

•

Check the fuses in the power termination box.

A group of modules, (a column or block)
which share the same power supply
assembly, fail to work.

•

Check the wire connections at the power
supply.

•

Check power to modules.

•

Replace the power supply assembly.

Entire display fails to work.

•

Check for proper line voltage into the power
termination panel.

•

Check for correct power to controller and
modules.

•

Check fuse in power termination panel.

•

Check/replace the ribbon cable from the
controller to the modules.

•

Check the voltage settings on the power
supplies.

•

Verify proper use of the software in the V1500
Controller manual (ED13530).

•

Replace the controller.

•

(For direct displays) Check the signal cable to
the controller using the loopback test.

Temperature always reads –196F/-127C
degrees F/ C

•

Check temperature sensor connections.

•

Replace the temperature sensor.

•

Replace the controller.

Display is stuck on bright or dim.

•

Check Manual/Auto dimming in Venus 1500
software.

•

Check light detector cable.

•

Check the address on the Light Sensor.

•

Check light detector for obstructions.

•

Replace the light detector.

•

Replace the controller.

Advertising