RS422 Interconnection
The Quick Connect cable is the most common method of terminating signal between
two displays. The ten-foot cable goes from the RS422 OUT on the first display to the
RS422 IN on the second display.
If the displays are not back-to-back, or
are too far apart for the quick connect
interconnect cable to reach, a 4-
conductor shielded cable of the correct
length is used. One end will connect at
the “RS422 OUT” 6-position controller
board terminal block (A31-TB3) in the
first display, and terminate on the
“RS422 IN” 6-position controller board
terminal block (A31-TB2) on the second
display. When not using the provided
quick connects cable, the cable should be in conduit.
Figure 34: RS422 Interconnection
Face A RS422 Out
(A31-TB3)
Field Cabling
Face B RS422 IN
(A31-TB2)
Pin 1 (GND)
Shield
Pin 6 (GND)
Pin 2 (D2OUT-N)
Red
Pin 5 (D1IN-N)
Pin 3 (D2OUT-P)
Black
Pin 4 (D1IN-P)
Pin 4 (D2IN-N)
Green
Pin 3 (D1OUT-N)
Pin 5 (D2IN-P)
White
Pin 2 (D1OUT-P)
Pin 6 (Shield)
Pin 1 (Shield)