background image

Note: Power supplies are preset. Contact Daktronics Customer Service for the proper
settings.

5. Fans are located along the bottom of the display to draw in cool air, which

exits out through vents located in the face at the top of the display

Figure 20: Control Component Locations

4.4 Display Access

Daktronics Galaxy AF-3300 series displays are
front accessible; meaning access to the internal
components can be gained only from the front of the
display.

Maintenance and Troubleshooting

4-3

1. Locate the latch access fasteners on the

module (one is centered below the second
row of pixels and one is centered above the
bottom two rows)

2. With a

1

/

8

" Allen wrench, turn the latch

access fasteners a quarter turn as shown in

Figure 21

on the 12 mm modules, one

latch turns clockwise and the other
counter-clockwise to open, and the reverse to close. On the 20 mm modules
turn both latches counter-clockwise to open and the reverse to close.

Figure 21: Removing a Module

3. Gently pull the module far enough forward to reach behind the back and

disconnect the power and ribbon cables


When installing a module, reverse the previous steps and take note of the following
points.

The weather-stripping on the back edge of the module must be intact and in
good condition if it is to prevent water from seeping into the display