Daktronics G-1000-34-R User Manual
Page 20

Electrical
Installation
3-4
J-Box
Field Cabling
Terminal Block (Data In)
Pin 1 (N.C.)
Pin 2 (N.C.)
Pin 2 (RX-P)
Clear
Pin 3 (TX-P)
Pin 3 (GND)
Shield
Pin 4 (GND)
Pin 1 (TX-P)
Black
Pin 5 (RX-P)
Pin 6 (N.C.)
3.4.2
RS/422
Reference Drawings:
Signal/Power Termination Panel . . . . . . Drawing A-88427
System Riser Diagram (422) . . . . . . . . . Drawing A-92681
One end of the signal cable should be terminated to the 10 position terminal block in the display
labeled “DATA IN” (TB42). Drawing A-88427 is an example of the termination panels. The
other end is terminated at the signal converter (Daktronics part number 0A-1127-0237) in the
control room.
Signal Converter (J4/J5)
Field Cabling
Terminal Block (Data In)
Pin 1 (GND)
Red
Pin 1 (GND)
Pin 2 (RX-P)
Black
Pin 2 (TX-P)
Pin 3 (RX-N)
Brown
Pin 3 (TX-N)
Pin 4 (TX-P)
White
Pin 4 (RX-P)
Pin 5 (TX-N)
Blue
Pin 5 (RX-N)
Pin 6 (GND)
Green
Pin 6 (GND)
Shield (Bare)
N.C.
3.4.3
Modem
Reference Drawings:
System Riser Diagram (Modem) . . . . . Drawing A-88426
Signal/Power Termination Panel . . . . . Drawing A-88427
Terminate the signal telephone wires in TB42 as follows:
Telephone Wires
Terminal Block
N.C.
Pin 1
N.C.
Pin 2
TIP-P
Pin 3
Ring-P
Pin 4
N.C.
Pin 5
N.C.
Pin 6