Datatek HP-UX 10.20 (32 bit kernel User Manual

Page 10

Advertising
background image

I P - C o m m K i t I n s t a l l a t i o n a n d A d m i n i s t r a t i o n G u i d e

f o r H P - U X – I s s u e 2 – R e l e a s e 1 . 0 . 2 2

10/13/11

Datatek Applications Inc.

10

IP-DSU Loopback Status ==> Loopbacks are not enabled.

IP-DSU Data Encryption Status ==> Disabled.

Actual IP-DSU Service State ==> Not Connected.

Local MAC Address ==> 0.19.5.84.49.56

Local IP Address ==> utm_ip_address

Subnet Mask ==> subnet_mask

Gateway IP Address ==> gateway_ip_address

IP-DSU Destination IP Address ==> host_ip_address

SNMP Trap Manager ==> Not defined.

Check the address and subnet mask fields that you entered. If they are correct, enter the

following command to restore the UTM to service.

<TRK-UNIV>

rs

The UTM has many useful console commands that are not described here. See section 4 of the

UTM User’s Manual for a complete description. Once you have done the initial configuration of

the UTM through the console port, you can access all console commands through the LAN port

via telnet. For example, you should be able to telnet to the UTM from the host on which you

installed the IP-CommKit software.

3.4 BNS

N

ODE

C

ONFIGURATION

If you are upgrading a CPM-HS module to a UTM, you don’t need to make any changes to the

BNS node configuration. You can simply remove the CPM-HS module and its I/O distribution

board, and install the UTM and its I/O distribution board in the same slot. The UTM appears as a

CPM-HS module to the controller in the BNS node.