Chapter 2 Hardware Installation
Chapter 2
LCD/Inverter Power Select
2-3 On: +5V
1-2 On: +12V
(default)
1
3
2
1
3
2
JP21 is used to select the power level of LVDS LCD inverter connector.
JP21
Panel Power Select
JP19 is used to select the power supplied with the LCD panel.
Important:
Before powering-on the system, make sure that the power settings of JP19 match
the LCD panel’s specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
JP19
1-2 On: +12V
3-4 On: +5V
5-6 On: +3.3V
(default)
5
1
3
2
4
6
5
2
4
6
1
3
5
2
4
6