Venting through wall – Drolet ECO-65 User Manual

Page 11

Advertising
background image

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.


WARNING: DO NOT INSTALL IN BEDROOM

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND

CEILING/ROOF MUST BE MAINTAINED


CAUTION:

THE CHIMNEY CONNECTOR SHALL NOT PASS TROUGH AN ATTIC OR ROOF SPACE,
CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING.



1.6.1. Equivalent Vent Length (EVL)

The longer the run of pipe in your installation, the
greater the restriction in your system.

Always use 4” pipe

Horizontal runs shall not exceed 9 feet.

Never exceed 30 feet of EVL.


To calculate EVL, use the following conversions table:

Qty

Type of pipe

EVL equivalent(ft)

1

90°

elbow or “T”

5

1

45° elbow

3

1 ft

Horizontal pipe run

1

1 ft

Vertical pipe run

0.5


Here is an example on how to calculate the EVL of
your installation. (See Figure 9):

(3 x 4‟ of vertical length = 12‟ x 0.5 = 6 EVL) +

(1 x elbow or "T" = 5 EVL) +

(2 x 1‟ of horizontal length = 2 EVL)

Total EVL = (6 + 5 +2) = 13.



1.6.2. Installation Configurations

a) HORIZONTALLY THROUGH WALL

(Refer to figures 10,11, or 12)

NOTE: Follow v

ent chimney manufacturer‟s instructions.


1. Position stove, adhering to clearances shown in Figures 1 & 2.

2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5).

3.

Always maintain 3” clearance from combustible materials.

FIGURE 10

Venting through wall