Drolet ECO-65 User Manual

Page 25

Advertising
background image

3.3.

VENTING SYSTEM MAINTENANCE

REGULARLY EXAMINE THE FLUE PIPES, THE JOINTS, AND THE SEALING TRIMS TO ENSURE

THAT THE SMOKE AND THE COMBUSTION GASES ARE NOT TRANSPORTED INTO THE AIR

DUCTING SYSTEM.


The most efficient method to sweep the venting system is by using a 4-inch pellet brush. Brush downwards so
ash, soot and creosote residues will come off the inner surface and fall at the bottom of the venting system
where they can be removed easily. The chimney must be in good condition and kept clean.


If a significant layer of creosote has accumulated (3mm /

1/8” or more), it must be removed immediately

to eliminate the risk of a chimney fire.

3.3.1. Dealing with a Chimney Fire


Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow
these steps:


1. Immediately turn off the stove;

2. Alert your family of the possible danger;

3. If you require assistance, alert your fire department;

4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use

water as it may cause a dangerous steam explosion;

FIGURE 21

Clean out trap and Pressure tap

location

Advertising