Power connection, Ez 4300 – Digi-Star EZ4300 User Manual

Page 6

Advertising
background image

EZ 4300

2

Power Connection

Warning! Disconnect the indicator power cord before jump-

starting or fast charging a battery.

Disconnect all indicator leads before welding on

equipment. Damage may occur to the indicator and

load cells.

Connect the power cable directly to a 12 Volt vehicle battery or to a 12 volt

regulated power supply.
Connect the RED wire from the power cable to +12 VDC and the BLACK wire to

GROUND. The indicator is fused internally at 4 amps.
Attach the scale end of the power cable to the J901 connector located on the

bottom panel of the scale.

Power Cable

Wire Color Wire Function

RED

Battery(+12VDC)

BLACK

GROUND

ORANGE

Remote Alarm Out+

BLUE

Remote Input (Rotation Counter)

Remote Alarm Connections

If a remote 12 VDC alarm is to be used, connect the +12VDC side of the alarm to

the power cable ORANGE wire and the GROUND side of the alarm to the frame

(=ground).

Note: The alarm output is fused for a maximum drain of 10 amps. The remote alarm

connections may also be used for motor control purposes when used with a

relay.

Remote Input Connections

If the remote input is to be used, connect on the side of the normally open

momentary switch or relay contact to the power cable BLUE wire, and the other

side to the frame or other GROUND connection. If your power cable does not

contain a blue wire and you desire to use this feature, contact your dealer for a

special cable. A process control box is available for motor control and remote

enter preset capability.

Advertising