Owner’s manual, Operating heater, Installation – Desa CCL3930NR User Manual

Page 15: Continued

Advertising
background image

15

107553

OWNER’S MANUAL

For more information, visit www.desatech.com

1.

STOP! Read the safety information
in columns 1 and 2.

2.

Make sure equipment shutoff valve
is fully open.

3.

Set selector switch in the OFF position.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you oper-
ate heater with doors closed,
heat buildup inside fireplace will
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open damper or window to vent
smell. This will only last a few hours.

OPERATING
HEATER

WARNING: Burners will come

on automatically within one
minute when the remote selector
switch is in the ON position after
the pilot is lit.

Continued

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

WARNING: Damper handle

will be hot if heater has been
running.

4.

Press in and turn control knob clock-
wise

to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, columns 1 and 2. If you
don’t smell gas, go to the next step.

Figure 33 - Control Knob and Ignitor Button Location

O

F

F

PIL

OT

O

N

L O

I H

REMOTE
OFF
ON

Control Knob

Ignitor Button

Selector Switch in OFF Position

Flame Adjustment Knob

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

Note:

Home owners generally prefer to

operate their heater with the chimney
damper closed. This will put all the heat
into the room. However, there may be
times you will desire the full flames of the
Hi heat setting but will find the heat output
excessive. You can open the chimney
damper (if you have one) fully or partially
to release some of the heat.

AU

TO

OFF

ON

7

Figure 32 - Installing Crossover Log (#7)
to Model CCL3930NR Only

Middle
Log (#2)

Pegs

Crossover
Log (#6)

Holes

AUT

O

OFF
ON

6

Figure 31 - Installing Crossover Log (#6)
(CCL3930NR Shown)

Pegs

Log #2

Front Log (#1)

INSTALLATION

Continued

Advertising
This manual is related to the following products: